HL7 has published the FHIR ValueSet, "MedicalDevicesSnomedCtUvIps." This set aggregates all SNOMED CT codes that are descendants of the concept 49062001 (Device), standardizing the coding for medical devices. This improves the interoperability of medical device information within FHIR environments.
cloudimg provides Snowstorm, the official open-source SNOMED CT terminology server, running on Ubuntu 24.04. This server enables scalable access to SNOMED CT clinical terminology through both a REST API and a standards-based HL7 FHIR terminology API.
SDS and iSecure Solutions propose a connected health data fabric built on standards like HL7 and FHIR. This fabric integrates hospitals, laboratories, and insurers, consolidating disparate medical data to manage longitudinal patient records from a single source of truth.
This article provides concrete JSON examples for major healthcare resources, including patient data, lab results, conditions, and medication records, based on the FHIR R4 standard. Each example not only shows the valid resource structure but also details common mistakes and the specific error messages reported by validators.
The EU's EHDS regulation (Regulation (EU) 2025/327) grants EU residents the right to access and share their electronic health data. It mandates common data exchange formats (based on FHIR) and interoperability requirements for software, with key obligations starting in 2029 and 2031.
A FHIR data platform ingests data from every sourceβincluding EHRs, claims, and remote devicesβand standardizes it using HL7 FHIR. This process transforms raw data from mere exchange into unified, analytics-ready insights for AI and population health.
The article outlines the complex technical challenges of building a clinical copilot that goes beyond simple language generation. It emphasizes that the system must accurately manage complex clinical context, such as result status, medication lifecycle, data source discrepancies, and authorization checks, using EHR and FHIR integration.
Firemetrics provides a platform that integrates and translates data from various system formats into FHIR. It supports major standards like LOINC, SNOMED CT, and DICOM, ensuring data validation and centralized management.
Despite the massive growth of the electronic health record market, mere digitization does not guarantee true data sharing. Achieving interoperability requires ensuring the exchange, interpretation, and usability of patient information across different systems, addressing technical, structural, and semantic barriers.
SEOSiri developed AquaShield MCP, a system that integrates data from environmental sensors and IoT pulse oximeters. This system analyzes water quality data and patient vital signs in real-time, providing structured medical information in HL7 FHIR v4.0.1 format to establish an early public health warning system.
The data integration engine, Ignifyr, is used across multiple European research projects to map diverse clinical site data into a common, FHIR-based data model. This process enables the integration of data for use by AI and advanced analytics tools.
This article discusses Reverse ETL for FHIR, a process designed to move curated clinical data products (such as readmission risk scores) from data warehouses back into the Electronic Medical Record (EMR) for clinical action. It details how to ensure data reaches the point of clinical decision-making rather than remaining in BI tools.
Helix EMR provides functionality to manage clinical research data by structuring it directly from routine care records. By linking trial information and biobank specimen data to the patient record, it enables data export in FHIR R4 format using standard terminologies like LOINC and SNOMED CT, thereby promoting research utilization.
International organizations like the WHO advocate that establishing data standards and interoperability is crucial for strengthening pandemic and epidemic disease reporting. Adopting international standards such as HL7 and FHIR, and utilizing common vocabularies like SNOMED CT and LOINC, significantly improves the quality and efficiency of data exchange during crises.
MedX offers a platform built on a single FHIR data store. It integrates four core pillarsβAutomation, Assistant, Registry, and Workspaceβto ensure data flows seamlessly from devices and labs to clinical intelligence and analytics systems.
Phronexis announced a demonstration of an engine that integrates fragmented patient records from multiple sources with different structures, such as HL7v2, CCDA, and FHIR. The system demonstrated the ability to construct a single, reliable timeline by tracking every decision process in an auditable manner.
This article details the FHIR R4 ImagingStudy resource. This resource handles metadata related to DICOM imaging studies, providing structured information such as which patient was studied, what type of image was taken, and when. It establishes a foundation for searching and linking image data within electronic health records.
The SQL on FHIR WG plans to define ViewDefinition as an 'additional resource' in R6. Separately, two approaches were discussed for terminology querying: tabular abstraction versus using FHIRPath functions.
A developer built a pipeline that processes both clinical data formats, FHIR R4 bundles and raw HL7v2 messages, normalizing and validating them into a single internal model. It is implemented in Go and serves the data via GraphQL API and FHIR REST API.
Rhapsody Health offers a comprehensive platform to integrate clinical systems and diverse data sources. Supporting standards like FHIR and HL7v2, it aids low-code development through Corepoint integration and supports tasks from data transformation to log analysis via an integrated AI assistant, aiming to solve complex healthcare IT challenges.