Hypertension Patient Screening: Implementing with CQL and Measure
ι«θ‘ε£η ζ£η―©ιΈ - CQL/Measure ε―¦δ½ - HackMD
Summary
This article details how to identify hypertensive patients meeting specific criteria using Constraint Query Language (CQL) and FHIR Measures. Based on the Taiwan version of CMS-165, it outlines a process for generating a list of patients requiring medication management by combining historical diagnoses and recent blood pressure measurements.
Details
The article provides a technical solution to the clinical problem of 'Hypertension Patient Screening' using CQL (Constraint Query Language) and Measure resources within the FHIR standard. Specifically, based on the Taiwan version of CMS-165 requirements, the implementation is detailed in several steps: 1. **Diagnosis Criteria (Denominator)**: Identifying patients with the ICD-10-TW code 'I10' (Hypertension). 2. **Observation Data Retrieval**: Obtaining final blood pressure measurements using a Taiwan-specific profile (Observation-bloodPressure-twcore). 3. **Extraction and Evaluation of Latest Values (Numerator)**: Extracting systolic (LOINC: 8480-6) and diastolic (LOINC: 8462-4) pressures from the most recent measurement, and evaluating if they meet the target criteria of being less than '140/90 mmHg'. This implementation also notes that CQL is a developing standard and points out technical limitations due to the current prevalence of HAPI FHIR on domestic FHIR servers. The final output is a Measure report integrating the patient's diagnosis and blood pressure management status.